跳到正文
Environmental Science & Technology· He·· 6 天前AI 评分34

生物过滤对饮用水净化中消毒副产物控制的影响:一篇批判性综述

Impacts of Biological Filtration on Disinfection Byproduct Control during Drinking Water Purification: A Critical Review

AI 导读

这篇发表于 Environmental Science & Technology 的批判性综述指出,生物过滤(生物活性炭与砂滤)对消毒副产物前体具有选择性去除:优先去除疏水性和高分子量 C-DBP 前体,而亲水性 N-DBP(如 HANs、NDMA)前体易穿透滤床并可能新生成。

AI 深度导读基于原文整理的分节解读
背景
生物过滤(尤其生物活性炭和砂滤)被广泛用作低化学、低能耗的屏障,用于削减消毒副产物前体。但生物滤池是活的、随时间演变的生态系统,可能从反应性前体的净「汇」转变为净「源」。
做法
这篇综述综合已有证据,梳理生物过滤对前体的选择性去除规律,并归纳前体生成机理:生物膜脱落释放富含胺与核酸的胞内有机物,可溶性微生物产物与胞外聚合物持续产生和脱落抬高类蛋白DON,滤料老化与分层削弱去除效果。作者还用回归分析估算N-DBP前体去除的汇—源转换点。
结论
生物过滤呈选择性去除:疏水性和高分子量C-DBP前体优先被去除,亲水性N-DBP(如HANs、NDMA)前体易穿透,甚至可能新生成。回归分析估算N-DBP前体去除的汇—源转换约在log10(床体积)=5.38(约240,000床体积)。作者还识别出氧化剂预暴露、温度波动和营养化学计量比等关键运行临界点。
意义
作者提出面向风险的框架,主张开展前体特异性监测(如荧光指纹)并结合智能工艺控制,以稳定生物滤池性能、应对新出现的遗传毒性风险。汇—源转换的床体积估算为水厂提供了实用参考,但其适用条件仍待检验。

原文摘要

出版方登记 · Crossref

Biofiltration, particularly biological activated carbon and sand filtration, is widely implemented as a low-chemical, energy-efficient barrier to attenuate disinfection byproduct (DBP) precursors. However, biofilters are living, time-evolving ecosystems that can transition from a net “sink” to a net “source” of reactive precursors. This review synthesized evidence that biofiltration exhibits selective removal: hydrophobic and high-molecular-weight C-DBP precursors are preferentially removed, whereas hydrophilic N-DBP (e.g., HANs, NDMA) precursors readily break through and may be newly produced. The authors clarified the mechanistic basis of precursor generation, highlighting (i) biofilm turnover that releases intracellular organic matter enriched in amines and nucleic acids, (ii) continuous production and sloughing of soluble microbial products and extracellular polymeric substances that elevate protein-like DON, and (iii) media aging and stratification that diminish removal efficacy. Regression analysis estimated sink–source transition for N-DBP precursor removal at approximately log10(bed volumes) = 5.38 (∼240,000 bed volumes), a practical reference in drinking water treatment plants. Furthermore, the authors identified critical operational tipping points, including oxidant pre-exposure, temperature fluctuations, and nutrient stoichiometry, that can trigger this functional inversion. Finally, a risk-oriented framework is proposed, advocating for precursor-specific monitoring (e.g., fluorescence signatures) and intelligent process control to stabilize biofilter performance against emerging genotoxic risks.

页面未能读取全文,以上为出版方登记的摘要;方法与图表见原文

本页是 AI 精读,不转载论文原文;完整论文(含方法、图表与参考文献)见原文

来源:Environmental Science & Technology · doi.org