以 C2H4 为反应气消除 99Ru 同量异位素重叠,三重四极杆 ICP−MS 实现大体积海水 99Tc 准确测量
Overcoming Ru-99 Isobaric Overlap via C2H4 as a Reaction Gas for Tc-99 Accurate Measurement in Large-Volume Seawater Samples by Triple Quadrupole ICP−MS with Mass-Shift Mode
发表的研究以 C2H4 作为反应气,在三重四极杆 ICP−MS 的质量偏移模式下消除了 99Ru 对 99Tc 的同量异位素干扰,无需再依据 Ru 同位素比值做数学校正。
- 背景
- 环境中超痕量 99Tc 的准确测定长期受 98Mo 与 99Ru 的干扰制约。99Ru 与 99Tc 质量数相同,构成同量异位重叠,质谱测量时无法靠质量分辨把两者分开。常规应对办法是按已知的 Ru 同位素比(如 99Ru/102Ru)做数学校正,把 99Ru 的计数从 99Tc 信号中扣除;原文指出,这种做法会给 99Tc 带来较高的测量不确定度。大体积海水样品基体量大、99Tc 含量极低,上述干扰与校正带来的不确定度叠加,使超痕量 99Tc 的直接、准确测定难以实现。
- 做法
- 研究对象是体积大于 20 L 的海水样品。前处理用 Fe(OH)2 与 Ti(OH)3 两种共沉淀剂共同预富集 99Tc,把大体积水样中的超痕量核素浓缩到小体积;随后用两根串联的 TEVA 树脂柱纯化,这一步对 Mo 的去污因子为 5×10^5,对 Ru 为 1×10^5。测量环节使用三重四极杆 ICP−MS/MS,以 He−C2H4 作为反应气,并在质量移位(mass-shift)模式下采集信号,借 C2H4 的高反应活性去除化学纯化后仍残留的 98Mo 和 99Ru。原文称,这是首次在 mass-shift 模式下完全去除这两种残留干扰。方法以整个流程的去污因子、检出限和单样品分析时间作为衡量指标,并与传统方法作对比。
- 结论
- 整个流程对 98Mo 的去污因子达到 1×10^12,对 99Ru 达到 1.6×10^9,原文称这一水平比传统方法高 3−4 个数量级。方法对 99Tc 的检出限为 0.015 pg/L,单个样品的全流程分析时间少于 20 h。由于 99Ru 的干扰在测量环节已被去除,测定过程不需要任何基于 Ru 同位素比的数学校正,原文把这一点作为本方法区别于常规做法的直接结果。也就是说,大体积海水中的 99Tc 可以走一条从共沉淀、TEVA 纯化到 ICP−MS/MS 质量移位的贯通流程,最终得到的是不经校正的测量值。
- 机制
- 该结果之所以成立,关键在于把干扰去除拆成两段:化学纯化先把 Mo、Ru 的总量压低,TEVA 柱对 Mo 的去污因子为 5×10^5、对 Ru 为 1×10^5;残余部分再在质谱端处理。原文给出的解释是 C2H4 反应活性高,在 mass-shift 模式下与干扰离子反应,使其离开 99Tc 的检测质量位置,从而被完全去除。与此相对,数学校正路线的不确定度源自对已知 Ru 同位素比的依赖:校正是否准确,取决于所采用的比值是否与实际样品中的 Ru 相符。
- 意义
- 对于需要处理大体积海水、目标物又处在超痕量水平的 99Tc 测定,这条路线省掉了 99Ru 数学校正这一环节,也就省掉了由该校正引入的不确定度分量。原文以「有望」(expected to)的措辞表述其用途:在不做任何 99Ru 数学校正的前提下,直接、准确地测量大体积海水样品中的超痕量 99Tc。
原文摘要
出版方登记 · CrossrefAccurate determination of ultra-trace level 99Tc in environmental samples is primarily hindered by the interferences of 98Mo and 99Ru. For the “elimination” of the 99Ru isobaric overlap during the mass spectrometry measurement, the commonly-used method of mathematical correction based on a known isotopic ratio of Ru (e.g., 99Ru/102Ru) could lead to a high measurement uncertainty of 99Tc. In this work, a direct and accurate analytical method of 99Tc in large-volume seawater samples (>20 L) was developed using two TEVA resin columns in combination with ICP−MS/MS in He−C2H4 mode. Both Fe(OH)2 and Ti(OH)3 were used as co-precipitants for the pre-concentration of 99Tc in large-volume seawater samples, and then, 99Tc was purified by two serial TEVA resin columns with the high decontamination factors of Mo (5×105) and Ru (1×105). Based on the high reactivity of C2H4, the residual interferences of 98Mo and 99Ru were completely removed in the mass-shift mode for the first time. Excellent decontamination factors of 98Mo (1×1012) and 99Ru (1.6×109) were achieved in the whole procedure, which was 3−4 orders of magnitude higher than these of traditional methods. The detection limit of 0.015 pg/L for 99Tc was obtained, and the whole analysis time was less than 20 h per sample. This method is expected to directly and accurately measure ultra-trace level 99Tc in large-volume seawater samples without any mathematical correction of 99Ru.
页面未能读取全文,以上为出版方登记的摘要;方法与图表见原文
本页是 AI 精读,不转载论文原文;完整论文(含方法、图表与参考文献)见原文
来源:Analytical Chemistry · doi.org